CARRIER 58SS PDF

Application data, 58ss/dh induced-combustion gas-fired furnaces, Installation guidelines procedures • Read online or download PDF • Carrier 58SS/DH User. Carrier Furnace Model 58SSBC (58SSBC) Parts – Shop online or call Fast shipping. Open 7 days a week. day return policy. Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline.

Author: Tusida Kagalkree
Country: Burkina Faso
Language: English (Spanish)
Genre: Software
Published (Last): 4 August 2006
Pages: 229
PDF File Size: 9.34 Mb
ePub File Size: 1.37 Mb
ISBN: 734-6-49715-527-4
Downloads: 18269
Price: Free* [*Free Regsitration Required]
Uploader: Yorisar

Use these procedures in conjunction with your specific furnace installation instructions. What is this old floor. You may not post new threads. When a furnace is installed so that the supply ducts carry air to areas outside the space containing the furnace, the return air must also be 58s by duct s sealed to the furnace casing and terminating outside the furnace location area.

All fuel-burning furnaces must be supplied with air.

A lot of engineering has gone into the valve design, and I’m not going to offer any thoughts on how to alter it’s operation.

What you have is known as a dual-redundant valve. BB code is On. Find all posts by Skip Locate furnace close to chimney and as near to the. They also reflect current conditions found in the field, and conform to existing national standards, and safety codes. If yes, the hold coil is working, if no the hold coil has failed. Door and drawer rubber stoppers. Always comply with cafrier. Refer also to your gas supplier regulations and local.

Provide ample space for servicing and cleaning.

Carrier 58SS Manuals

When a furnace is installed so that the supply ducts. Always comply with minimum fire protection clearances shown on unit rating plate.

Manufacturer carrer the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. It does add a bridge rectifier, not sure what the point of that is How many new Breakers can I add to panel? Find all posts by neurocutie. I don’t understand why it is so important to have a separate pick and hold coil But I did consider that one way to totally replicate the original functions of the separate pick and hold coils on my current valve the one with the blown hold coil is to feed both pick and hold signals in with diodes on each signal basically a diode OR gate.

  JURNAL KESLING PDF

It should work as long as the valve is carrirr enough with the half-wave AC input and will prevent the sparker from being on all the time The only side effect I can see is that the pilot gas won’t flow til the inducer switches on the hold coil I don’t know what activates the sail switch or where it is located but it seems as if it is not closing to the hold coil.

S-2XA Pg 1 Replaces: If you could post a picture of the wiring diagram you are looking at I might be able to answer your questions. The desire to conserve energy.

Carrier 58SS 3SI Gas Furnace Owners Manual

As always when troubleshooting the thermostat must be calling for heat. After a few seconds the main burner should come on. If no main burner take a voltage reading at 1 and a ground or common terminal on the valve. I dunno if it is even worth replacing the valve at this point, particularly since the new valve doesn’t even have separate pick and hold coils to begin with I already know what they carroer say.

Complain wrong Brand wrong Model non readable. It looks like the sparker does indeed stay on all the time because of the different circuit design. Any ideas on what I should do to get it to catrier sparking when the pilot burner senses the flame?

It seems like if I just wire the pick carrer direct to the 24V power yellowand then leave the spark circuit on the pilot switch, everything will be fine, no? I think your problem is either in the sail switch 7Vthe pilot switch 6H the connector 10B4 or 10B2 or perhaps the interconnecting wiring.

  ALEXANDRE DEULOFEU MATEMATICA DE LA HISTORIA PDF

The relief-air supply for the draft safeguard duct draft. The condition is further affected by the growing use of kitchen and bathroom exhausts and even fireplaces. Carrier 58ss gas furnace dead: Under all eonditions, enough air must be provided to ensure there will be no negative pressure condition. Can water bypass my filter???

Carrier 58SS/DH User Manual | 8 pages

Replacement air must be provided by means of ducts from the outside to the furnace area or heated. The relief-air supply for the draft safeguard duct draft hood must be in the same atmospheric pressure zone as the combustion-air inlet supply to the furnace. Well, in looking at the specs for the replacement gas valve EF32CW for the originalit seems that my original contention is somewhat confirmed: Actually I kinda worried that this new replacement valve will cause the sparker to be on all the time, no?

Aprilaire – Basic Solenoid Question.

I have nothing to say. At first I thought the problem was with the pilot switch LH because the thing would never switch over from pilot to main.

Carrier 58SS 3SI Gas Furnace Owners Manual

Originally Posted by furd. Kinda looks that way to me Seperate the pilot at the molex plug and the wiring going to the furnace install a jumper in the green and caerier holes. Originally Posted by nartkram.